Neutral pH Surgical Instrument Cleaners are recommended by the manufacturers of Surgical Instruments.
Virtually all manufacturers of surgical instruments, rigid scopes, flexible scopes, and instrument containers recommend the use of neutral pH Cleaning Concentrates. Generic  Example of this recommendation: Do not use high acidic (pH <4) or high alkaline (pH >10) products for disinfection or cleaning, since these can corrode metal, cause  discoloration or stress fractures. Neutral pH Surgical Instrument Cleaners are recommended by the manufacturers of Surgical Instruments. Neutral pH Surgical Instrument Cleaners prevent Surgical Instrument Corrosion. Neutral pH Surgical Instrument Cleaners remove stains. Do not use abrasive pads or abrasive Cleaning Concentrates , which will scratch the surface allowing dirt and water deposits to collect. Abrasive cleaning will remove the protective passive layer. Do not use Cleaning Concentrates  with high concentrations of chlorine bleach to clean or disinfect stainless steel instruments, as pitting will occur. Never use bleach to clean any surgical instruments.  The high pH of bleach causes surface deposits of brown stains and might even corrode the instrument.  Even high quality stainless steel is not impervious to an acidic  bleach solution. Sort instruments by similar metal for subsequent processing so that electrolytic deposition (galvanic corrosion) due to contact between dissimilar metals will not occur.
Surgical Instrument Cleaners
Buy neutral ph surgical instrument cleaners that avoid surgical instrument corrosion.
Use neutral ph surgical instrument cleaners that avoid surgical instrument pitting.
cleaning eye surgical instruments
Surgical Instrument Cleaners
Buy neutral ph Enzymatic Surgical Instrument Cleaners.
Surgical Instrument Cleaners and Endoscope Cleaners
Tap water can contain many minerals, which may discolor and stain surgical instruments.  It is recommended that de-ionized water be used for the final rinsing to prevent  spotting. all-in-one or combination cleaning concentrates can be effective in treating unacceptably hard source water and removing hard water encrustation from surgical  instruments and equipment.  If untreated tap water is used for final rinsing, then the instruments must be dried immediately to avoid staining. Do not allow blood and debris to dry on the instruments. If cleaning must be delayed, place groups of instruments in a covered container with appropriate enzyme-detergent or apply an enzyme-detergent foam spray to delay drying. The use of pre-soaking enzyme-detergent foam sprays have been shown to reduce the time expended for manual cleaning and render higher quality outcomes. After surgery, open all box locks and disassemble instruments with removable parts. This will limit blood  drying on instruments that may cause them to corrode. The all-in-one cleaners and the enzyme-detergent foam sprays deliver a chemical complex to: maintain the hydration of bioburden, prevent corrosion, clean the surface, and condition the surface of instruments. This can significantly reduce manual cleaning and facilitate cleaning the surface of surgical instruments, scopes, and the lumens of cannulated instruments inside-and-one. If used properly, all-in-one enzyme detergent foam sprays and/or all-in-one combination cleaning concentrates can render excellent outcomes and facilitate cleaning instruments and scopes inside-and-out. They effectively cleaning the surface while cleaning lumens and working channels. This can eliminate or reduce the manual labor expended, rendering lower reprocessing costs while improving turnaround.
Surgical Instrument Cleaners
Ultrasonic cleaners are very effective when used with hot water per manufacturer’s recommended temperature and specially formulated detergents. It is recommended that all visible debris and blood be removed from the instrument prior to ultrasonic cleaning. Contact between dissimilar metals can cause corrosion when Ultrasonics is applied.  Sort surgical instruments according to similar metal types to prevent corrosion. (electrolytic deposition - galvanic corrosion) It is not recommended to clean plated instruments in an ultrasonic cleaner since the ultrasonic vibration and the presence of other sharp surgery instruments may crack or rupture the plating. Ultrasonic Cleaners do not provide the complete "proper sequence of treatments" i.e. purified final rinse(s) that are purified, purged between treatments and/or have temperatures elevated to disinfection levels. Ultrasonic Cleaning can effectively remove: long term encrustation and surgical cements or glues that have dried onto instrumentation. Overloading, and  low water temperature, will decrease the effectiveness of ultrasonic equipment.
Ultrasonic cleaners are most effective when used with hot water per manufacturer’s recommended temperature and with "high level" multi-tiered enzyme detergents. It is recommended that all  visible debris and blood be removed from the instrument prior to ultrasonic cleaning. Sort instruments by similar metal for subsequent processing so that electrolytic  deposition (galvanic corrosion) due to contact between dissimilar metals will not occur. It is not recommended to clean plated surgery instruments in an ultrasonic cleaner since the ultrasonic vibration and the presence of other sharp instruments may crack or rupture the plating. Always refer to the printed manufacturer recommendations prior to using Ultrasonics.
Surgical Instrument Lubricants 
Surgical Instrument Lubrication 
To maintain moving parts and protect instruments from staining and rusting during sterilization and storage, they should be lubricated with a water-soluble, preserved  lubricant after each cleaning. Most automated washer decontaminators provide the option for lubrication at the end of the final rinse treatment. Since effective ultrasonic  cleaning removes all lubricant, re-lubrication is important. "all-in-one" cleaning concentrates will provide lubrication. The lubricant should contain a chemical preservative to prevent bacterial growth in the lubricant bath. The bath solution should be made with de-mineralized water. A lubricant containing a rust inhibitor helps prevent electrolytic corrosion of points and edges. Immediately after cleaning, instruments should be immersed or rinsed for 30 seconds and allowed to drain off, not wiped off. A lubricant film  will remain through the sterilization to protect surgery instruments during storage. Staining and spotting may result if residual chemicals are not completely rinsed from surgery instruments that are subjected to steam sterilization. Following the manufacturer’s recommendations for the proper sequence of treatments (cold water pre-wash, enzyme-detergent wash, purified water rinse/lubrication, and drying) is critical to prevent stains and spots. A Cleaning Concentrates that will avoid spotting are "free-rinsing" or "rinse clean".
Studies regarding the passive layer of Surgical Instruments
(Guidelines on metals and alloys in contact with food; Council of Europe; published 11.10.2000. Systemic nickel: the contribution made by stainless steel cooking  utensils; Contact Dermatitis, Volume 32:2, 1994) of the stainless steel passive layer to prevent corrosion have revealed a reduction in corrosion prevention with the use of cleaning concentrates that are not neutral pH. The use of cleaning concentrates that deliver an acid rinse will release nickel from the stainless steel and decrease the efficacy of  the passive layer. This is most critical on initial reprocessing events of stainless steel surgical instruments. Measurable levels of nickel have been detected. It was also  shown that, as the number of subsequent uses increased, the level of nickel release diminished and reached a steady state (measured in the order of μg/l). These  observations reflect the changes that occur in the passive oxide layer on first immersion of stainless steels in aqueous media.
What is a Stainless Steel Surgical Instrument?
Stainless steel is essentially a low carbon steel which contains chromium at 10% or more by weight. It is this addition of chromium that gives the steel its unique stainless,  corrosion resisting properties. The chromium content of the steel allows the formation of a rough, adherent, invisible, corrosion-resisting chromium oxide film on the steel  surface. If damaged mechanically or chemically, this film is self-healing, providing that oxygen, even in very small amounts, is present. The corrosion resistance and other  useful properties of the steel are enhanced by increased chromium content and the addition of other elements such as molybdenum, nickel and nitrogen. Stainless steel has  a passive film created by the presence of chromium (and often other alloying elements, nickel, molybdenum) that resists this process. When exposed in air, stainless steels  passivate naturally (due to the presence of chromium). But the time required can vary. In order to ensure that the passive layer reforms rapidly after pickling, a passivation  treatment is performed using a solution of nitric acid and water.

How Surgical Instrument Cleaners maintain the Passive Layer
The passive layer or stainless steel prevents corrosion.
Passivation and Polishing eliminate the carbon molecules  form the instrument surface. This forms a layer which acts as a corrosive resistant seal. Passivation is a chemical process that removes carbon molecules from the surface  of the instrument. This chemical process can also occur through repeated exposure to oxidizing agents in chemicals, soaps, and the atmosphere. Polishing, by the manufacturer, is a process used to achieve a smooth surface on the instrument. Surgical Instruments are polished because the passivation process leaves microscopic pits where the  carbon molecules were removed. Polishing also builds a layer of chromium oxide on the surface of the surgery instrument. Proper cleaning, handling, and sterilization will build up the layer of  chromium oxide and protect the Surgical Instrument from corrosion and /or pitting. In some circumstances older instruments have higher resistance to corrosion than new ones. The newer instruments have not had the time to build up the chromium oxide layer. Improper cleaning and sterilization can cause the layer of chromium oxide to disappear or become damaged thus increasing the possibility of corrosion and/or pitting. Proper cleaning and sterilization can cause the layer of chromium oxide to improve over time thus decreasing the possibility of corrosion and/or pitting. Second only to the financial asset value of the working staff, the surgery instrument and scope inventory is the single most financially valuable asset of the healthcare facility. It is important to properly clean, sterilize, handle, and store your instruments.

John Temple
Product Development