Glassware Washers
that deliver accurate washer disinfecting temperatures.
Glassware Washer Dimensions
Usable Chamber Size:
  • 26” wide x 26" high x 29" deep
Overall Unit Size:
  • 42" wide x 80" high x 36" deep 
Scroll Down for LYNX 610LX  Laboratory Glassware Washer  Specifications
Surgical Instrument Washer Specifications
Surgical Instrument Washers manufactured in the USA.
Glassware Washer SIZE
  • Compartment usable space:
26” wide x 26" high x 29" deep
  • Overall Unit*”:
42" wide x 80" high x 36" deep Sliding Door(s)

Glassware Washer STANDARD FEATURES

Glassware Washer CONFIGURATION (select one):
  • front load and unload
  • pass through load and unload The The LYNX 610 LX Surgical Instrument Washer is provided with an unload door and an additional cycle status indicator on the unload end, allowing  one-way product flow from the contaminated area to the clean area.

The LYNX 610 LX Laboratory Glassware Washer shall be provided with a combination of rotating jet spray and direct spindle spraying for all treatment solutions. The LYNX 610 LX Surgical Instrument Washer spray system  consists of a single rotating spray arm mounted above, and interchangeable spindle wash or a rotating jet spray arms mounted below for internal treatment of the racked items. The bottom header automatically couples to the re-circulated wash/rinse treatment system.

Laboratory Glassware Washer VIEWING WINDOW
Washer door(s) shall be provided with a full view, tempered, double  glass viewing window.

STAINLESS STEEL TREATMENT COMPONENTS
All treatment components, including jet spray system, screens, pump,  and recirculating piping are constructed of 304 stainless steel.

Glassware Washer PERSONNEL SAFETY FEATURES
Opening the load-end door (or unload-end if pass-through unit),  automatically stops operation of the washer. The door(s) must be  closed, alarm acknowledged, and the “Cycle Start” button depressed to  continue operation.
An Emergency Stop (ES) button is provided on the load-end control panel  (and unload-end if pass-through unit). If the operations of the wash  cycle are interrupted by depressing the (ES) Button, the operator must  reset the button and push the “Cycle Start” button to continue  operations from the beginning of the selected cycle.

MULTI CYCLE COLOR/GRAPHIC MICRO COMPUTER CONTROL SYSTEM
A solid-state microcomputer control system monitors and automatically  controls all process operations and functions. A twelve-cycle treatment  menu may be programmed and retained to permit operating personnel to  accommodate a wide variety of loads and processing requirements.  Individual cycle phase times and temperatures and other key process  parameters are programmable. Each cycle may be locked by supervision to  ensure process integrity. The Cycle programming may be controlled by a  supervisory access code. Each cycle program may be reviewed on demand.

Glassware Washer AUTOMATIC TREATMENT CYCLE
The standard treatment cycle consists of any or all of the following  phases: Pre-wash, Wash, Rinse, Wash II, Rinse and Final Rinse. All  cycle phases may be selected or deselected by the user. All Wash and  Rinses treatments are re-circulated under pump pressure except the  optional non-re-circulated rinse. The cycle, once activated, is  completely automatic.

REMOVABLE DEBRIS SCREENS
Located in the sump, easily removable screens are provided to protect  items and large debris from entering the recirculation system.

WATER SAVINGS
Water from the last rinse cycle may be held and utilized as the  pre-wash of the next cycle.

TEMPERATURE GUARANTEE
The operator may select to guarantee the temperatures for any re-circulated phase of the cycle. If the temperature guarantee is selected, the phase will not begin timing until the re-circulated water temperature reaches the set point. If the re-circulated temperature drops below the set point during the phase, the timer will stop. Once  the set- point temperature is again met, the phase-timer continues from  where it stopped thus assuring the set temperature during entire  treatment phase time.

Glassware Washer OPERATION
The operator loads the items to be cleaned in the wash chamber, closes  the door, selects the proper cycle, and depresses the “Cycle Start”  button. The washer proceeds through the treatment schedule and  automatically shuts off at the completion of the cycle. The operator  then opens door and removes the cleaned items.

Glassware Washer
TREATMENT SCHEDULE
(Programmable with any or all phases below.)

PRE-WASH
Either Hot water from the house supply fills the sump, or Water  remaining in the chamber sump from final rinse of the previous cycle is  re-circulated through the jet system under pump pressure and pumped to  drain upon completion. Phase is adjustable from 0 – 9999 seconds in  1-second intervals and 120F - 190F in 1 intervals.

DETERGENT  WASH
Hot water from the house supply fills the sump and is pumped through  the jet system. As required, a specified amount of detergent is added  during recirculation using the OPTIONAL LYNX- supplied, or customer  supplied detergent injection pumps. At the end of the treatment, the  detergent solution is pumped to drain. Phase is adjustable from 0 –  9999 seconds in 1-second intervals and 120F - 190F in 1 intervals.

RINSE
Hot water from house supply fills the chamber sump and is re-circulated  through the jet system under pump pressure to remove residual  detergent. Re-circulated water is pumped to drain on completion of  treatment.

DETERGENT  WASH II
Same as Detergent Wash phase – allowing a secondary detergent to be  utilized.

PURIFIED WATER RINSE(S)
Hot water from house supply fills the chamber sump and is re-circulated  through the jet system under pump pressure to remove residual  detergent. Re-circulated water is pumped to drain on completion of  treatment.

Glassware Washer FINAL SANITARY WATER RINSE
Load is sprayed with either re-circulated or an OPTIONAL  non-re-circulated sanitary water system. At the end of the treatment,  the water may be retained in the chamber sump for use as the pre-wash water in the subsequent load or directed down the facility drain. The Re-circulated phase is adjustable from 0 – 9999 seconds in 1-second intervals and 120F - 190F in 1 intervals.

Glassware Washer CONSTRUCTION
The base, wash chamber and chamber sump are constructed of #304  Stainless Steel.  The Washer frame and cabinet, door and hardware are  #304 Stainless Steel. 
The LYNX 610 LX Laboratory Glassware Washer is provided with vertical sliding doors. The chamber door(s) are of double-wall construction A tempered double-pane, full view glass  observation window is provided in each door.

The LYNX 610 LX Laboratory Glassware Washer is insulated with a moisture resistant protective covering.

The LYNX 610 LX Laboratory Glassware Washer chamber sump is equipped with a level control switch, automatic  water fill port, and a stainless steel heating coil for the  re-circulated treatment solutions. The control system displays and  monitors re-circulated solution temperatures. Sump is completely  drained after each phase, preventing cross-contamination between treatment phases and cycles.

All re-circulated treatments are under pressure of a stainless steel  3Hp pump. This system is equipped with a solid state pressure sensor.

The LYNX 610 LX Laboratory Glassware Washer is equipped with a transformer for the control circuit;  integral Type-2 coordinated protective magnetic starters requiring no  upstream fuses for overload protection of all motors, and all other  electrical components required for the operation.

An top-mounted light is provided to illuminate the wash chamber.

The LYNX 610 LX Laboratory Glassware Washer is equipped with pneumatically actuated valves to control  the output of the pump to the jet system.

The LYNX 610 LX Surgical Instrument Washer is inter-piped and inter-wired so that only one connection  is required for each service or utility.

The LYNX 610 LX Laboratory Glassware Washer is supplied with four (4) threaded detergent injection ports  and electrical pump connections.

Programming is in Military time and Fahrenheit temperature. Times and  temperatures are expressed in seconds and full-degree increments,  respectively.

A highly visible color touch screen displays cycle program data on demand and real-time in-process cycle performance. All cycle deviations  are alarmed both visually and audibly and must be acknowledged by the operator.

The LYNX 610 LX Laboratory Glassware Washer is designed to meet specifications by placing all utility  services on either the right-hand or left-hand side of the washer, as  viewed from the load-end.
The LYNX 610 LX Laboratory Glassware Washer is provided with one (1) additional dry electrical contact  for control for external damper(s) installed in the facility HVAC  system (by customer).

A modem is provided for online service diagnostics, evaluations, and  software upgrades. If required by the customer, this system shall allow  for immediate access to the unit’s control system by a factory service  engineer.  The factory trained personnel will have the ability to  troubleshoot, identify system malfunctions, and recommend repairs to  local maintenance personnel within minutes of a malfunction.  A dedicated analog phone line is required to utilize the Modem feature.

Glassware Washer OPTIONAL FEATURES

The LYNX 610 LX Laboratory Glassware Washer is equipped with a dryer. Heated air is re-circulated  throughout the chamber at a user-selected temperature:
The LYNX 610 LX Laboratory Glassware Washer is provided with automatic power activated doors. The operator may open and close the door(s) by the push of a button.  If  the unit is a double door (pass-through) configuration the automatic  door logic will be interlocked to allow only one door to be opened at a  time.

The LYNX 610 LX Laboratory Glassware Washer is provided with a cold-water inlet valve, integral with  the drain line to add cold water during draining for assistance in  reducing the effluent temperature.  A cold-water connection is required  when this option is selected.

Vapor created during the wash and rinse phases are collected and  directed through internal scavenger exhaust ports to an OPTIONAL Vapor Condenser or to the building exhaust.

A vapor condenser requiring no input of water is provided to remove  residual vapors from the wash chamber and to direct the condensed  vapors to drain.
The LYNX 610 LX Laboratory Glassware Washer is provided with an air compressor inter-wired and  inter-piped with the automatic control system to supply the air demand  required by the washer. The compressor is supplied with regulator,  filter, and a holding tank.

The LYNX 610 LX Laboratory Glassware Washer is provided with a high-altitude treatment pump for installations where the elevation is 3000 feet or above sea-level.

The LYNX 610 LX Laboratory Glassware Washer is designed to comply with Seismic Zone 3 and 4  requirements.

The LYNX 610 LX Laboratory Glassware Washer is provided with a printer to record all cycle program  parameters and process performance data. Each program time/temperature  profile may be printed as required.

The LYNX 610 LX Laboratory Glassware Washe features an Ethernet port is provided to permit the capability of  downloading cycle real-time performance data to a remote computer  terminal. Custom software may be provided to accommodate specific  applications.

The main control panel is inspected and labeled in accordance to the UL  standards.

The LYNX 610 LX Laboratory Glassware Washe is equipped with an integral #316 Stainless Steel tank with level control, automatic fill and overflow protection. Heating is  accomplished via either steam or electric heat up to 190F.

Glassware Washer ACCESSORIES

The washer is provided with a stainless steel trim flange to enclose the opening between one end of the washer and the masonry wall opening.

A stainless steel modular wall assembly is designed and manufactured to enclose an open wall area or to create a wall barrier. All materials  and fasteners are of stainless steel construction.

A stainless steel transfer cart is provided to connect to the load or  unload end of washer for accessories transportation and ease of loading  of the washer.
Surgical Instrument Washers manufactured in the USA.
LYNX 610LX  Laboratory Glassware Washer
Surgical Instrument Washers manufactured in the USA.
deliver washer disinfecting thermal rinse temperatures.
Laboratory Glassware Washers
deliver washer disinfecting thermal rinse temperatures.
Surgical Instrument Washers manufactured in the USA.
Glassware Washers that are:
  • Manufactured in the USA,
  • deliver reliable long lasting performance,
  • built with nonproprietary, locally available replacement parts
Glassware Washers
Surgical Instrument Cleaner for cleaning surgical instruments cleaner.
Surgical Instrument Cleaner for cleaning surgical instruments cleaner.
Surgical Instrument Cleaners
Surgical Instrument Cleaners
Surgical Instrument Washer Disinfector
easy FOAM-it Surgical Instrument Cleaner
 Instrument Washer Detergents
Surgical Instrument Cleaner Surgical Instrument Washers
Surgical Instrument Enzyme Detergent Cleaner
Surgical Instrument Washer Disinfectors, Surgical Instrument Cleaners
Surgical Instrument Washer Disinfectors, Surgical Instrument Cleaners
Surgical Instrument Washer Disinfectors, Surgical Instrument Cleaners